It accords with the national standard GB/T 1409-2006, GB/T 1693-2007, American Standard ASTM D150 and IEC60250 specifications.
Class C digital Q frequency range is 10kHz ~ 60MHz, is a multifunctional,multipurpose, multi range digital impedance test instrument. It is based on theprinciple of series resonance, the voltage ratio scales of Q value. It can measure theQ value of the high frequency inductor, inductance and distributed capacitance;capacitance and loss angle. With a dedicated fixture BH916 dielectric loss device also on high frequency dielectric loss of solid insulating materials (tan delta) and Permittivity (epsilon), high frequency circuit in parallel and series resistance, the characteristic impedance of the transmission line were investigated. The Q table in accordance with the national metrological verification regulations: "JJF1073-2000 high frequency Q calibration specification".
1 characteristics:
Read the technology of automatic Q of the company innovation value, the Qresolution to 0.1Q.
The synthesis of DPLL 1kHz ~ 70MHz, the test signal.
In the low to 20nH residual inductance, high frequency to ensure error is smaller by Q value.
Multi parameter of the special LCD screen menu display: Q value, the test frequency,the tuning status.
The Q value range automatic / manual range control.
The digital Q value preset, can improve the speed and reliability of the batch test.
2 main technical indexes:
The 2.1 test signal frequency range: 1kHz ~ 70MHz, digital synthesis, digital set oradjusted continuously, five effective digital display.
2.2 Q value range: 1 ~ 1000 four bit digital display, resolution 0.1Q. In 100, 316, 999third, range can be automatically switched.
2.3 Q values inherent error: ± 5% ± 3% of full scale value.
2.4 the effective inductance measurement range: 0.1 µ H ~ 1000mH.
The 2.5 inductance measurement error: = 5% ± 0.02 µ H
2.7 Q preset function: Q preset range: 1 ~ 1000 may. The measured piece reaches a preset value "GO" display and beep prompt. The unqualified parts is displayed "NOGO".
2.8 dimensions and weight: 415 x 180 x 170 (mm), 6.5kg.
BH916 dielectric loss test device (Shu Xian)
Dielectric loss test device and the C BH916D Q table and the inductor with theinsulating materials, high frequency dielectric loss tangent (tan delta) and Permittivity(epsilon) test. It accords with the national standard GB/T 1409-2006, GB/T 1693-2007, American Standard ASTM D150 and IEC60250 specifications.
The testing device is composed of a micrometer capacitor plate, plate capacitor is usually used to clamp the sample, equipped with the Q table as indicating instrument.Insulating material loss angle tangent value is calculated by the formula of scale reading changes through the tested sample into the panel capacitor and do not put it in the samples of Q value change and the thickness of the obtained. Similarly, thescale reading changes of the panel capacitor, to obtain the dielectric constant is calculated by a formula.
The 1 job characteristics
1.1 the panel capacitor:
1.1.1 sheet size:
WY916D-38: a 38mm.
WY916D-50: a 50mm.
The 1.1.2 pole spacing adjustable range and resolution:
≥ 8mm, ± 0.002mm
The 1.2 fixture plug spacing:
25mm + 1mm
The 1.3 fixture loss angle tangent value
≤ 2.5 × 10-4
Table two, LKI-1 inductance group typical test data
Coil test frequency distributions of Q values of P inductance capacitance
9 100KHz 989.4 25mH
8 400KHz 13811.4 4.87mH
7 400KHz 20216 0.99mH
6 1MHz H
5 2MHz 1988.7 49.8 μ
4 4.5MHz 231710 H
3 12MHz 1936.9 2.49 μ
2 12MHz 2296.4 0.508 μ
1 25MHz 50MHz 2332110.9 0.125 μ