您好, 歡迎來到包裝印刷網(wǎng)! 登錄| 免費注冊| 產(chǎn)品展廳| 收藏商鋪|
當前位置:美鈞金屬(上海)有限公司>>鋁合金>> ACP5080RS
| 參 考 價 | 面議 |
產(chǎn)品型號
品 牌
廠商性質(zhì)其他
所 在 地
更新時間:2021-07-23 08:41:11瀏覽次數(shù):471次
聯(lián)系我時,請告知來自 包裝印刷網(wǎng)ACP 5080(R)S
for Vacuum Chamber Applications
On the base of EN AW 5083 aluminum cast alloy, alimex developed a top quality cast material for
the most challenging and critical applications of innovative, high-end industries like the
Electronics, Semiconductor, Solar and Display Panel industry.
Through decades of practical application experience, continuous material research, development
and testing, ACP 5080(R)S provide good mechanical and physical properties as compared with
similar competitors’ cast and rolled aluminum plates.
Material excellence and superiority is achieved through the proprietary smelting, manufacturing,
processing and handling procedures and specifications employed in the production of this grade.
2
ACP 5080(R)S
for Vacuum Chamber Applications
Special features
? Especially homogenized
? Stress relieved
? Ultrasonic tested
? Reduced micro-porosity
? Tested by:
? Fraunhofer Institut für Chemische Technologie
? Forschungszentrum Julich (Outgasing test and Helium leak test)
3
ACP 5080(R)S
Outgassing Test
Description of the test:
Residual gas and outgassing measurements were performed on 3 casted aluminum plates (ACP 5080S).
Before measurements were made, the specimens were subjected to a cleaning procedure according
to FZJ-COSY specifications (10 min ultrasonic cleaning at 60 °C in hydrocarbon-free, alkaline
washing solution pH 8.5 – 9.0).
The investigations were performed on two specimen at room temperature, and for one specimen
the temperature was increased to 160 °C for 12 h during the measuring process. The curve of the
partial pressure against time was recorded for selected atomic masses (AMU). At the
beginning and end of these trend measurements, analogue measurements were
recorded for the entire measuring range (AMU 1 –200).
For measurement results please take a look at the attached Outgassing Test.
4
ACP 5080(R)S
Helium Leak Test
Description of the test:
On 5 plates casted from aluminum (ACP 5080S), long-term measurements of the helium-permeability,
according to the local vacuum method (DIN EN 1779 – A3), were carried out. A possible He-leakage
should be measured for 24 hours testing time.
Subsequently all testing parts are connected separately to the intake flange of the leak-detectorand
sealed with aluminum gaskets ?Ultra-Dichtring“ from LEYBOLD (see draft, schematic test assembly,
attachment 1, fig 1 u. 2). From the inner diameter of the sealing ring a measuring area of A = 822
mm2 x π/4 = 5278 mm2 is calculated. All objects were cleaned with alcohol before
testing. The measurements were carried out at a differential test pressure of
?p = 1 bar and room temperature (~25°C).
For measurement results please take a look at the attached Helium Leak Test.
請輸入賬號
請輸入密碼
請輸驗證碼
以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關(guān)企業(yè)負責,包裝印刷網(wǎng)對此不承擔任何保證責任。
溫馨提示:為規(guī)避購買風險,建議您在購買產(chǎn)品前務必確認供應商資質(zhì)及產(chǎn)品質(zhì)量。