久久久久日韩在线,超碰日韩二区,福利午夜在线观看91,欧美日日精品久,亚洲情色天堂,亚洲综合色情在线,成人毛片色图888,国产AV香蕉久久,九九热精品5

產(chǎn)品|企業(yè)|供應(yīng)|求購|資訊|展會|技術(shù)

96040A Low Phase Noise Reference Source

參考價面議
具體成交價以合同協(xié)議為準(zhǔn)
  • 公司名稱成都中盛興業(yè)科技有限公司
  • 品       牌
  • 型       號
  • 所  在  地成都市
  • 廠商性質(zhì)其他
  • 更新時間2024/12/14 19:15:17
  • 訪問次數(shù)117
產(chǎn)品標(biāo)簽:

在線詢價收藏產(chǎn)品 點(diǎn)擊查看電話
  成都中盛興業(yè)科技有限公司(以下簡稱"成都中盛"或"公司")目前已經(jīng)成為電子測試與科學(xué)分析領(lǐng)域?qū)I(yè)的綜合服務(wù)商。  "成都中盛"通過與業(yè)務(wù)伙伴的緊密合作,憑借營銷服務(wù)網(wǎng)絡(luò),致力于為客戶提供專業(yè)、方便、快捷的本地化服務(wù)?! ∥宜究蛻羯婕肮I(yè)電子制造、文教科研、通信以及信息技術(shù)、微電子、新能源、生物醫(yī)藥等多個領(lǐng)域,通過與mikron、Texio、Plexlogger、foundrax、M+P、Rigol Agilent、Fluke、Tektronix、TE、、R&S、Anritsu、keithley等廠商的合作,為客戶提供產(chǎn)品開發(fā)設(shè)計、系統(tǒng)集成、產(chǎn)品增值銷售、應(yīng)用解決方案、維修維護(hù)和等綜合服務(wù)?! ?成都中盛"將繼續(xù)通過不懈的努力,為客戶提供"更豐富的產(chǎn)品選擇、更經(jīng)濟(jì)的解決方案、更全面的專業(yè)服務(wù)",成為本領(lǐng)域的專家。
超臨界流體色譜(SFC)
96040A Low Phase Noise Reference Source 產(chǎn)品信息

96040A Low Phase Noise Reference Source

Simplify your RF calibration system

The Fluke Calibration 96040A RF Reference Source enables you to simplify your RF calibration system by replacing many of the instruments and accessories that make up your current system. Its precision signal level and attenuation, high signal purity and precision low distortion modulation make this reference source superior to the general-purpose signal generators that are often used to calibrate spectrum analyzers, modulation meters, RF sensors, attenuators, and similar instruments. Its low phase noise provides superior phase noise performance.

Unlike many RF calibration solutions, the 96040A is designed specifically for RF calibration, with a calibration-oriented user interface that makes it easy to learn and use. The 96040A speeds up calibration procedures, reduces opportunities for operator errors, and greatly simplifies RF metrology. As the core of an RF and microwave calibration system, the 96040A covers the majority of test points required for calibrating spectrum analyzers of any frequency range.

Automated with MET/CAL® Plus Calibration Management Software, the 96040A reduces complexity and calibration times, dramatically improving efficiency and increasing capacity by 50 % or more over manual methods.

Key benefits

  • Covers a broad range of RF calibration workload
  • Reduces the number of instruments and interconnections required for your RF calibration system
  • “What you set is what you get” accurate signal delivery direct to the DUT input
  • Integrated 50 MHz frequency counter eliminates need for an additional instrument • Calibration-specific interface simplifies technician tasks
  • Simplifies uncertainty calculations by delivering known signals direct to the device under test (DUT)
  • Lowers RF system maintenance costs
  • With automation, reduces spectrum analyzer calibration times by as much as 50% over manual methods

Broad, versatile workload coverage

The 96040A calibrates a broad workload of RF calibration devices, including:

• Spectrum analyzers

• Modulation meters and analyzers

• RF power meters and sensors

• Frequency counters

• Attenuators

• And more

The metrology associated with calibrating these items becomes simpler because you have fewer error sources and uncertainty contributions to consider.

More than just an RF calibrator

There are many applications in research and development, manufacturing test, and ATE needing better performance than a general purpose signal generator. If wide frequency coverage, frequency resolution, low harmonics, phase noise and spurious content, signal level and attenuation accuracy, or dynamic range are critical parameters the 96040A is an ideal solution.

Cut the cost of your RF calibration system in half

As the central instrument in a high capability RF spectrum analyzer calibration system, the 96040A can cut your costs in half. The 96040A replaces all of these parts of a “typical” RF calibration system:

Up to four signal sources (from audio/ function generators to RF signal and low phase noise sources)

  • Power meters and power sensors
  • Step attenuators
  • Filters
  • Pads
  • Couplers
  • 50 MHz frequency counter

The 96040A not only reduces the initial need to purchase, install and configure RF system components, but it also reduces the maintenance and calibration costs associated with all of that equipment. The 96040A is also easier to transport than a heavy rack of equipment and accessories, making it a good solution for on-site calibration.

With its 4 GHz frequency range, the 96040A performs more than 80 % of all the tests required on high performance, high frequency spectrum analyzers.

For workload items that require frequencies beyond 4 GHz, you can use an RF and microwave source that you probably already own alongside the 96040A to address the few remaining higher frequency test points. For many spectrum analyzer models operating below 4 GHz, you only need a 96040A to perform the entire calibration. You can’t simplify much more than that!

No need for additional function generators

The 9640A Reference Source’s internal modulation capability makes it suitable for applications that require precision modulation to be applied to the output signal, such as modulation analyzer calibration and spectrum analyzer sweep time testing using an AM signal with more accurate modulation rates. You don’t need additional function generators as a low frequency modulation source—the 96040A delivers it all.

Designed for RF calibration

The 96040A user interface is designed to simplify processes for calibrating typical items in your workload, such as spectrum analyzers, RF level meters and receivers. Parameter offset, stepping, relative and DUT error readout modes allow you to work accurately and efficiently, following familiar calibration procedures. You’ll find it easier than ever to determine the performance and tolerances of units under test.

The 96040A front panel is equipped with dedicated function keys, context-sensitive softkeys, and a bright, easy-to-read color display that make it easy to learn and operate. You can set output levels in terms of power (watts or dBm), voltage (RMS or peak to peak) using familiar multipliers and exponent forms. You can move easily between voltage, power and dBm units without losing entered values or accuracy. In error readout mode to adjust the reading, simply rotate the spin wheel and the DUT error is displayed directly in dB, ppm or percent.

The simple, calibration-oriented user interface also makes troubleshooting easier if you encounter an unexpected result or an out-of-tolerance condition while following a manual or automated calibration procedure.

“What you set is what you get” accuracy and signal purity

A rugged, precise levelling head delivers 96040A signal levels directly to the device under test (DUT) input just the way you set them on the front panel. This unique “What you set is what you get” feature helps you avoid problems like losses, noise, interference, and mismatch errors, which can be caused by using intermediate connectors and cables. This approach also maintains the integrity of low-level signals. The head maintains signal precision and noise immunity throughout a 154 dB dynamic range, down to the very lowest levels at -130 dBm.

The leveling head reduces lead changes from 25 to just 5 during a typical calibration, allowing you to “connect once and test many,” extending unattended times in an automated system, and reducing connector wear.

Calibrated as a system to assure system performance

The 96040A is supplied with a 50 ohm leveling head. The /75 model has both 50 ohm and 75 ohm leveling heads. Each mainframe and head are calibrated together as a complete system. System calibration helps assure overall system performance. Each 96040A instrument is supplied with a comprehensive ISO 17025 compliant certificate of calibration with data for all key parameters, including level and attenuation, output VSWR, and phase noise. You can be assured that your 96040A is traceable, plus RF metrology and uncertainty analysis become much simpler and faster. Accredited certification is available for the 96040A and both 50 ohm and 75 ohm heads.

State-of-the-art phase noise performance

With reduced low phase noise optimized for low and high offset frequencies and specifications from 1 Hz to 10 MHz offsets, the 96040A offers exceptional phase noise performance beyond that required for today’s high performance workloads.

Phase noise data is included in the 96040A certificate of calibration. Instead of relying only on the more conservative guaranteed specifications, users have actual performance data for their unit. Even with the best low phase noise signal generators, filters are commonly used during spectrum analyzer phase noise calibration tests, reducing noise levels at wide (high) offset frequencies to improve test margins. The 9600FLT 1 GHz bandpass filter accessory is designed specifically for high performance spectrum analyzer wide-offset phase noise testing and connects easily to 96040A models in either benchtop or rack-mounted applications.

Selectable frequency reference input/ output expands functionality

Selectable external frequency reference input is available as a standard feature on the rear panel of the 96040A. The input allows you to lock the frequency output to an external reference, such as the Fluke Calibration 910R Rubidium Standard, for applications where high clock accuracy or use of a common reference frequency is important. The frequency reference output allows a DUT to be frequency locked to the 96040A internal reference clock. This configuration is often required to reduce frequency offset errors that may occur between the reference source and the DUT.

Simplify frequency response tests with 96040A sweep functions

RF applications often require a frequency sweep. The 96040A’s sweep functions simplify the application of manual legacy spectrum analyzer frequency response testing, as well as filter response measurements.

Automate with MET/CAL® software for “walk-away” efficiency

In a typical automated RF calibration process, the operator must frequently intervene to change test setups, thus limiting the benefits that can be realized by the automation. Walk-away automation can increase calibration system capacity by up to 25 percent using procedures you develop in MET/CAL  Calibration Management Software. For example, the manufacturer’s calibration procedure for calibrating the Agilent E4407B 26.5 GHz spectrum analyzer requires 27 different and complex test setups. On the other hand, the 96040A, used with MET/CAL  Calibration Management Software, can perform the major core of required tests with a single setup. Only six additional setups would be needed using a MET/CAL procedure.

MET/CAL procedures created by Fluke Calibration for the 9640A models can be used by the 96040A in 9640A emulation mode. Optimized automated procedures can save time for the operators by allowing them to leave the system running while attending to other work. For example, the E4407B MET/CAL procedure for the legacy 9640A, running in emulation mode on the 96040A, allows for a total 90 minutes of “walkaway” time within the total two-hour calibration runtime.

Using the 96040A with other automation solutions

The 96040A is also integrated easily into existing automated systems and software. The time savings and efficiency gains offered by the 96040A can be realized by structuring test sequences to take full advantage of its “connect once measure many” capabilities.

The 96040A is designed to match or exceed the performance and functionality of the HP3335A and HP8662/3A in calibration systems. With HP3335A and HP8662/3A GPIB command emulation as standard, replacing these popular but obsolete and difficult-to-maintain products becomes just a plug-and-play substitution.

96040A summary specifications*
  Frequency specifications Level specifications
(50 Ω output, see extended specifications for 75 Ω)
Range 1 mHz to 4 GHz -130 to +24 dBm to 125 MHz, 14 dBm at 4 GHz (leveled)
Resolution 10 µHz 0.001 dB
Accuracy ± 0.05 ppm ± 5 µHz Down to -48 dBm: ± 0.03 dB to 100 kHz, ± 0.05 dB to 128 MHz, ± 0.3 dB at 4 GHz
10 MHz to 128 MHz: ± 0.05 dB to -48 dBm, ± 0.1 dB to -84 dBm , ± 0.7 dB at -130 dBm
Attenuation   ± 0.02 dB to 49 dB, ± 0.15 dB at 110 dB
Relative to +10 dBm, 10 Hz to 128 MHz
VSWR ≤ 100 MHz: ≤ 1.05, ≤ 2 GHz: ≤ 1.1, 2 GHz to 4 GHz: ≤ 1.0 + 0.05 xf (GHz)
Harmonics and spurious –60 dBc harmonics, –78 dBc spurious to 1 GHz
Phase noise at 1 GHz –144 dBc/Hz, typical, at 10 kHz to 100 kHz offset
Modulation AM, FM, PM, internal and external. Frequency pull and external leveling
Frequency sweep 1 mHz to 4 GHz. Linear or Logarithmic. Stop-Start or Center-Span
Frequency counter Internal 50 MHz frequency counter
Temperature Operating: 0 °C to 50 °C, 23 °C ± 5 °C for specified performance; Storage: -20 °C to +70 °C.
Standard interfaces IEEE-488.2 (GPIB)
GPIB command emulation 9640A, 9640A-LPN, 9640A-LPNX, HP3335, HP8662A, HP8663A.
Dimensions (HxWxD) 146 mm x 442 mm x  551 mm (5.8 in x 17.4 in x 21.7 in) including handles Industry-standard 19 in (483 mm) rack mounting when fitted with Y9600 rack mounting kit
Weight 18 kg (40 lb)
*Key specifications summary. Refer to the extended specifications for full and detailed specifications.

 

包裝印刷網(wǎng) - 包裝印刷行業(yè)專業(yè)網(wǎng)絡(luò)宣傳媒體

關(guān)于我們|本站服務(wù)|會員服務(wù)|企業(yè)建站|旗下網(wǎng)站|友情鏈接

Copyright ppzhan.com All Rights Reserved法律顧問:浙江天冊律師事務(wù)所 賈熙明律師

客服熱線:0571-87759927 投訴熱線:0571-88947171 網(wǎng)站客服:

對比
客服
手機(jī)站
詢價
反饋
回首頁

提示

×

*您想獲取產(chǎn)品的資料:

以上可多選,勾選其他,可自行輸入要求

個人信息:

克山县| 福海县| 孝昌县| 大新县| 邵阳县| 永康市| 奉节县| 沛县| 邻水| 南涧| 嘉鱼县| 阳山县| 称多县| 徐汇区| 东平县| 阿克苏市| 新和县| 绥芬河市| 海宁市| 虎林市| 收藏| 成安县| 讷河市| 伊吾县| 新乡市| 杨浦区| 宜宾市| 札达县| 重庆市| 连平县| 绥棱县| 遂溪县| 治县。| 海安县| 宣汉县| 郎溪县| 红原县| 娄烦县| 清远市| 剑川县| 滕州市|